Overview Location | not available |
---|---|
Picture Gallery | details... |
Geological Unit | Silt, clay, peat (bog, marsh) |
---|---|
Site Morphology Class |
T1 T1: flat; T2: slope; T3: ridge and T4: steep ridge; following Pessina and Fiorini (2014) A GIS procedure for fast topographic characterization of seismic recording stations, Soil Dynamics and Earthquake Engineering, 63, p248-258 |
Site Morphology Description | Fluvial geomorphology: alluvial slope, plain, cone |
Ground type EC8 | C |
Ground type SIA | D |
Basin Information | in sedimentary basin |
Reference | Hobiger Manuel, Bergamo P., Imperatori W. & Fäh D., "SITE CHARACTERIZATION REPORT Sennwald (SG) - Strafanstalt Saxerriet", Swiss Seismological Service, ETH Zürich, 2019 |
Location Code | 03 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | No housing, buried in the earth |
sensor depth below station | 2.5 m |
Distance to Building (m) | - |
Location Code | 05 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | No housing, buried in the earth |
sensor depth below station | 5.5 m |
Distance to Building (m) | - |
Location Code | 08 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | No housing, buried in the earth |
sensor depth below station | 7.5 m |
Distance to Building (m) | - |
Location Code | 12 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | No housing, buried in the earth |
sensor depth below station | 11.5 m |
Distance to Building (m) | - |
Location Code | 15 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | No housing, buried in the earth |
sensor depth below station | 14.5 m |
Distance to Building (m) | - |
Location Code | 19 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | No housing, buried in the earth |
sensor depth below station | 19.0 m |
Distance to Building (m) | - |
Location Code | BT |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | Borehole |
Housing Description | casing: plastic; casing length: 26m; inner diameter: 99mm; locking(mechanism: glass bead; wet) |
sensor depth below station | 97.6 m |
Distance to Building (m) | - |
Location Code | M1 |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | Borehole |
Housing Description | casing: plastic; casing length: 26m; inner diameter: 99mm; locking mechanism: glass |
sensor depth below station | 34.0 m |
Distance to Building (m) | - |
Location Code | SF |
---|---|
Opening Date | 08-07-2022 |
End Date | - |
Housing Class | free-field |
Housing Description | Borehole-pot, concrete vault, sensor bolted to the Foundation |
sensor depth below station | 0.4 m |
Distance to Building (m) | - |
Location code | 03 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | Pressure Sensor |
Sensor manufacturer | |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HDH |
Stream Noise (last week) | HDH |
Location code | 05 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | Pressure Sensor |
Sensor manufacturer | |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HDH |
Stream Noise (last week) | HDH |
Location code | 08 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | Pressure Sensor |
Sensor manufacturer | |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HDH |
Stream Noise (last week) | HDH |
Location code | 12 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | Pressure Sensor |
Sensor manufacturer | |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HDH |
Stream Noise (last week) | HDH |
Location code | 15 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | Pressure Sensor |
Sensor manufacturer | |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HDH |
Stream Noise (last week) | HDH |
Location code | 19 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | Pressure Sensor |
Sensor manufacturer | |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HDH |
Stream Noise (last week) | HDH |
Location code | BT |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | HypoSensor ES-DH |
Sensor manufacturer | Kinemetrics |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HGE , HGN , HGZ |
Stream Noise (last week) | HGE , HGN , HGZ |
Location code | M1 |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | HypoSensor ES-DH |
Sensor manufacturer | Kinemetrics |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HGE , HGN , HGZ |
Stream Noise (last week) | HGE , HGN , HGZ |
Location code | SF |
---|---|
On date | 08-07-2022 16:00:00 |
Off date | - |
Sensor model | EpiSensor ES-T |
Sensor manufacturer | Kinemetrics |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HGE , HGN , HGZ |
Stream Noise (last week) | HGE , HGN , HGZ |
Obtained from spectral modeling of small earthquakes with constant update.
See Edwards et al. (2013), Determination of Site Amplification from Regional Seismicity: Application to the Swiss National Seismic Networks. Seismological Research Letters, 84(4), 611–621.
H/V pick image: | |
---|---|
Authoritative Site Characterization Analysis | details... |
measurements nearby | list... |
---|