Station Overview

Overview Location not available
Picture Gallery details...
Network CH
Station Code EMV
Station Description Vieux-Emosson, VS
Latitude (WGS84) 46.06318
Longitude (WGS84) 6.89883
Station altitude (CH1903) 2130.0
running from 1981-11-18
...until 2012-06-08
Waveform Access open
Sensor Types Accelerometer Velocimeter
Geological Unit Gneiss
Site Morphology Class T2
T1: flat; T2: slope; T3: ridge and T4: steep ridge;
following Pessina and Fiorini (2014) A GIS procedure for fast topographic characterization of seismic recording stations, Soil Dynamics and Earthquake Engineering, 63, p248-258
Site Morphology Description Rock slope
Ground type EC8
Ground type SIA
Basin Information not in a sedimentary basin with possible 2D/3D effects
Reference
Resonance Frequency (Hz) 2.07
Uncertainty Factor -
Vs 30 (m/s) -
Location Map


Federal Office of Topograpy: National Map 1:25‘000
Topography Map


Federal Office of Topograpy: DHM25: Digital Height Model 1:25000
Geology Map

Federal Office of Topograpy: Geological map of Switzerland 1:500‘000

Sensor locations

Location Code AH
Opening Date 18-11-1981
End Date 2002-01-02
Housing Class -
Housing Description -
sensor depth below station 0.0 m
Distance to Building (m) -
Location Code FH
Opening Date 18-11-1981
End Date 1993-09-03
Housing Class Urban free field
Housing Description Sensors in small room just inside access tunnel, 15 m from 100 m high dam, 80 m directly below free surface, 3m from nearest entrance Sensors placed directly on concrete floor on rock. Cliff face.
sensor depth below station 0.0 m
Distance to Building (m) 30
Location Code (none)
Opening Date 03-08-1999
End Date 2012-06-08
Housing Class -
Housing Description -
sensor depth below station 0.0 m
Distance to Building (m) -

Current Instrumentation

No open epochs

Location code AH
On date 03-09-1993 00:00:00
Off date 2002-01-02 14:00:00
Waveform Access open
Sensor model Mk IIIA
Sensor manufacturer Willmore
Digitizer model AHP
Digitizer manufacturer HP
Channels SHZ
Location code AH
On date 30-09-1992 00:00:00
Off date 1993-09-03 00:00:00
Waveform Access open
Sensor model Mk IIIA
Sensor manufacturer Willmore
Digitizer model AHP
Digitizer manufacturer
Channels SHZ
Location code AH
On date 18-11-1981 00:00:00
Off date 1992-09-30 00:00:00
Waveform Access open
Sensor model Mk IIIA
Sensor manufacturer Willmore
Digitizer model AHP
Digitizer manufacturer HP
Channels SHZ
Location code FH
On date 18-11-1981 00:00:00
Off date 1993-09-03 00:00:00
Waveform Access open
Sensor model Mk IIIA
Sensor manufacturer Willmore
Digitizer model FHP
Digitizer manufacturer HP
Channels SHZ
Location code (none)
On date 08-10-2009 00:00:00
Off date 2012-06-08 00:00:00
Waveform Access open
Sensor model EpiSensor ES-T
Sensor manufacturer Kinemetrics
Digitizer model Trident
Digitizer manufacturer Nanometrics
Channels HGE , HGN , HGZ
Location code (none)
On date 08-10-2009 00:00:00
Off date 2012-06-08 00:00:00
Waveform Access open
Sensor model STS2_gen1
Sensor manufacturer Streckeisen
Digitizer model Trident
Digitizer manufacturer Nanometrics
Channels BHE , BHN , BHZ , HHE , HHN , HHZ
Location code (none)
On date 12-08-2004 00:00:00
Off date 2009-10-08 00:00:00
Waveform Access open
Sensor model EpiSensor ES-T
Sensor manufacturer Kinemetrics
Digitizer model HRD24
Digitizer manufacturer Nanometrics
Channels HGE , HGN , HGZ
Location code (none)
On date 26-11-2008 00:00:00
Off date 2009-10-08 00:00:00
Waveform Access open
Sensor model STS2_gen1
Sensor manufacturer Streckeisen
Digitizer model HRD24
Digitizer manufacturer Nanometrics
Channels BHE , BHN , BHZ , HHE , HHN , HHZ
Location code (none)
On date 03-08-1999 00:00:00
Off date 2008-11-25 23:59:59
Waveform Access open
Sensor model STS2_gen3
Sensor manufacturer Streckeisen
Digitizer model HRD24
Digitizer manufacturer Nanometrics
Channels BHE , BHN , BHZ , HHE , HHN , HHZ

Site Characterization

channel group
Empirical Amplification
CH.EMV..HG not available
CH.EMV..HH not available

Obtained from spectral modeling of small earthquakes with constant update.

  • Top: Fourier amplification with elastic (dashed line) and anelastic (solid line) amplification functions;
  • Centre: 5% damped response spectra amplification (anelastic);
  • Bottom: Number of recordings used.

See Edwards et al. (2013), Determination of Site Amplification from Regional Seismicity: Application to the Swiss National Seismic Networks. Seismological Research Letters, 84(4), 611–621.

H/V pick image:
Authoritative Site Characterization Analysis -
measurements nearby list...