Location Code | BT |
---|---|
Opening Date | 07-03-2022 |
End Date | - |
Housing Class | Borehole |
Housing Description | casing: metal; casing length: 1205 m; diameter: 24.4cm; locking mechanism: Hole lock; Casing completely filled with water, sealed on top with well head. |
sensor depth below station | 940.0 m |
Distance to Building (m) | - |
Location Code | SF |
---|---|
Opening Date | 07-03-2022 |
End Date | - |
Housing Class | Freefield |
Housing Description | concrete vault; Sensor placed directly on concrete foundation |
sensor depth below station | 0.5 m |
Distance to Building (m) | - |
Location code | BT |
---|---|
On date | 06-02-2024 00:00:00 |
Off date | - |
Sensor model | ABBT |
Sensor manufacturer | ASIR |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HG1 , HG2 , HGZ |
Stream Noise (last week) | HG1 , HG2 , HGZ |
Location code | SF |
---|---|
On date | 07-03-2022 07:37:00 |
Off date | - |
Sensor model | EpiSensor ES-T |
Sensor manufacturer | Kinemetrics |
Digitizer model | Centaur |
Digitizer manufacturer | Nanometrics |
Channels | HGE , HGN , HGZ |
Stream Noise (last week) | HGE , HGN , HGZ |
Obtained from spectral modeling of small earthquakes with constant update.
See Edwards et al. (2013), Determination of Site Amplification from Regional Seismicity: Application to the Swiss National Seismic Networks. Seismological Research Letters, 84(4), 611–621.
measurements nearby | list... |
---|